IMCInter Module Communication
v5.5.11

DVL Rejection

DvlRejection ID 358
Payload
10 bytes
Packet
32 bytes
Source
vehicle
Category
Navigation

When the vehicle uses Doppler Velocity Log sensor, this message notifies that a new measurement was locally rejected by the navigation filter.

#Fields

Offset FieldTypeUnitRangeDescription
0 #typeType of velocity uint8_t Bitfield –

This field represents the type of the rejected velocity.

0x01TYPE_GVGround velocity
0x02TYPE_WVWater velocity
1 #reasonReason uint8_t Enumerated –

Reason for rejection. There are two types of DVL measurement filters. An Innovation filter checks the innovation between the current measurement and the previous measurement within a certain amount of time and an Absolute filter compares the measurement with an absolute threshold value. Those filters are tested using horizontal speed measurements, i.e., measurements in the x-axis and in the y-axis.

0RR_INNOV_THRESHOLD_XInnovation Threshold - X

The current DVL x-axis measurement is discarded because the absolute difference between the value and the previous accepted DVL measurement with a given time window is above a configurable threshold.

1RR_INNOV_THRESHOLD_YInnovation Threshold - Y

The current DVL y-axis measurement is discarded because the absolute difference between the value and the previous accepted DVL measurement with a given time window is above a configurable threshold.

2RR_ABS_THRESHOLD_XAbsolute Threshold - X

The current DVL x-axis measurement is discarded because the the absolute value is above a configurable threshold.

3RR_ABS_THRESHOLD_YAbsolute Threshold - Y

The current DVL y-axis measurement is discarded because the the absolute value is above a configurable threshold.

2 #valueValue fp32_t m/s –

Value of the rejection. If it is an innovation rejection the value is the absolute difference between the previous accepted DVL measurement and the current one. If it is an absolute rejection the value is the current DVL measurement.

6 #timestepTimestep fp32_t s –

Timestep of the rejection. The timestep is 0 for an absolute rejection since it is an instantaneous reading. For innovation rejection it is the time difference between the previous accepted DVL measurement and the current one.