IMCInter Module Communication
v5.5.11

Emergency Control

EmergencyControl ID 554
Payload
≥ 3 bytes, variable
Packet
≥ 25 bytes
Source
ccu
Category
Plan Supervision

#Fields

Offset FieldTypeUnitRangeDescription
0 #commandCommand uint8_t Enumerated –
0ECTL_ENABLEEnable
1ECTL_DISABLEDisable
2ECTL_STARTStart
3ECTL_STOPStop
4ECTL_QUERYQuery
5ECTL_SET_PLANSet Plan
1 #planPlan Specification message<PlanSpecification> – –