UamTxRange

UamTxRange ID 818
Payload
≥ 8 bytes, variable
Packet
≥ 30 bytes
Source
ccu, vehicle
Category
Acoustic Communication

Request an acoustic modem driver to measure the distance to another system.

#Fields

Offset FieldTypeUnitRangeDescription
0 #seqSequence Id uint16_t – –

A sequence identifier that should be incremented for each request. This number will then be used to issue transmission status updates via the message UamTxStatus.

2 #sys_dstDestination System plaintext – –

The canonical name of the target system.

var #timeoutTimeout fp32_t s –

Maximum amount of time to wait for a reply.