IMCInter Module Communication
v5.5.11

Power Channel Control

PowerChannelControl ID 309
Payload
≥ 11 bytes, variable
Packet
≥ 33 bytes
Source
vehicle, ccu
Category
Actuation

This message allows controlling power channels.

#Fields

Offset FieldTypeUnitRangeDescription
0 #nameChannel Name plaintext – –

The name of the power channel.

var #opOperation uint8_t Enumerated ≤ 6

Operation to perform.

0PCC_OP_TURN_OFFTurn Off

Turn off power channel specified in field 'id'.

1PCC_OP_TURN_ONTurn On

Turn on power channel specified in field 'id'.

2PCC_OP_TOGGLEToggle

Toggle power channel specified in field 'id'.

3PCC_OP_SCHED_ONSchedule Turn On

Turn on power channel specified in field 'id' in 'sched_time' seconds.

4PCC_OP_SCHED_OFFSchedule Turn Off

Turn off power channel specified in field 'id' in 'sched_time' seconds.

5PCC_OP_SCHED_RESETReset Schedules

Reset all scheduled operations for the channel specified in field 'id'.

6PCC_OP_SAVESave Current State

Save the current state of the channel 'id' to persistent storage.

7PCC_OP_RESTARTRestart

Restart power channel specified in field 'id'.

var #sched_timeScheduled Time fp64_t s –

Scheduled time of operation.