IMCInter Module Communication
v5.5.11

Power Operation

PowerOperation ID 308
Payload
13 bytes
Packet
35 bytes
Source
vehicle
Category
Actuation

This message allows controlling the system's power lines.

#Fields

Offset FieldTypeUnitRangeDescription
0 #opOperation uint8_t Enumerated –

Operation type.

0POP_PWR_DOWNPower Down

Request the destination entity of this message to power down it's devices immediately. If the destination entity is the special entity '0' the whole system will power down.

1POP_PWR_DOWN_IPPower Down in Progress

The latest power down request is in progress and the time remaining until power down is given in field 'time_remain'.

2POP_PWR_DOWN_ABORTEDPower Down Aborted

The latest power down request was aborted.

3POP_SCHED_PWR_DOWNSchedule Power Down

Request the destination entity of this message to power down it's devices at the time given in the field 'sched_time'. If the destination entity is the special entity '0' the whole system will power down.

4POP_PWR_UPPower Up

Request the destination entity of this message to power up it's devices.

5POP_PWR_UP_IPPower Up in Progress

The latest power up request is in progress.

6POP_SCHED_PWR_UPSchedule Power Up

Request the destination entity of this message to power up it's devices at the time given in the field 'sched_time'. If the destination entity is the special entity '0' the whole system will power up.

1 #time_remainTime Remaining fp32_t s –

Time remaining to complete operation.

5 #sched_timeScheduled Time fp64_t s –

Scheduled time of operation.